Smokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste Incinerator

Product Details
Customization: Available
After-sales Service: 1 Years
Warranty: 1 Years

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
48
Year of Establishment
2014-04-30
  • Smokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste Incinerator
  • Smokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste Incinerator
  • Smokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste Incinerator
  • Smokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste Incinerator
  • Smokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste Incinerator
  • Smokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste Incinerator
Find Similar Products

Basic Info.

Model NO.
HLPG-300
Condition
New
Automation
Semi-Automatic
Screw
Twin-Screw
Treatment
Pyrolysis
Transport Package
Wooden Crate
Specification
2200*2100*3200
Trademark
Holy Shield
Origin
China
Production Capacity
500

Product Description

Technical Parameters:

Model

HLPG-30

HLPG-50

HLPG-150

HLPG-300

HLPG-500

Incineration Capacity

20-30kg/time
(3-6times/day)

30-50kg/time
(3-6times/day)

100-150kg/time
(3-6times/day)

200-300kg/time
(3-6times/day)

300-500kg/time
(3-6times/day)

Incineration Size(L×W×H)

1.45×0.9×1.92

1.8×1.15×2.2

2×1.2×2.48

2.2×1.57×2.87

3×1.75×3.07

Garbige Inlet Size(mm)

480×520

620×680

760×840

620×980

1080×1280

Chimney(mm)

Outer Diameterφ159

Outer Diameterφ219

Outer Diameterφ273

Outer Diameterφ325

Outer Diameterφ425

Induced Draft Fan

0.55kw

0.55kw

0.75kw

1.5kw

3kw

Combustion-supporting Device

Power0.13kw
Fuel consumption 2.5-5kg/h

Power0.13kw
Fuel consumption 2.5-5kg/h

Power0.17kw
Fuel consumption 5-10kg/h

Power0.17kw
Fuel consumption 5-10kg/h

Power0.17kw
Fuel consumption 5-10kg/h

Reburning Device

Power0.13kw
Fuel consumption 2.5-5kg/h

Power0.17kw
Fuel consumption 5-10kg/h

Power0.17kw
Fuel consumption 5-10kg/h

Power0.17kw
Fuel consumption 5-10kg/h

Power0.17kw
Fuel consumption 5-10kg/h

Opetating Voltage

380v or 220v

380v or 220v

380v or 220v

380v or 220v

380v or 220v

Weight(kg)

3000

4500

5300

6600

12000


 

 

 

Smokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste Incinerator
Technical principle:3T+E
Temperature: 550-850ºC in primary combustion chamber and 850-1200ºC in secondary combustion chamber

Time: The residence time of the secondary combustion chamber exceeds 2.0s

Turbulence: Greater turbulence can prevent large amounts of dioxins from being produced.

Ex-cessoxygen: Excess oxygen is added in the secondary combustion chamber and the mixed combustion chamber, so that the harmful gas produced in the combustion process of the primary combustion chamber is fully burned and processed, so as to achieve smokeless and tasteless effect

Smokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste IncineratorSmokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste Incinerator
Smokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste IncineratorSmokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste Incinerator
Smokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste IncineratorSmokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste Incinerator
Quality comparison
Smokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste Incinerator
Smokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste IncineratorSmokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste Incinerator
Our service

Smokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste Incinerator
Our customers

Smokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste IncineratorSmokeless Medical Incinerators Medical Waste Hospital Incinerator Medical Waste Incinerator
FQA
Q:Can you put my company brand (logo) on the products?
A:Yes,we support OEM/ODM service,the customize process as follows:
1: Customers put forward personalized customization requirementsCheap.
2:Our engineer draw the design draft.
3:Customer confirm the design draft.
4:Factory start to produce shipment.
Q:How to choose a Model?
A:You can tell us what you need, and we can help you choose the Model
Q:How to pay?
A:TT and L/C are acceptable and TT will be more appreciated
Q:What is the lead time of the shipment?
A:It depends on order quantities. Generally speaking, the delivery time will be within 2 to 4 weeks.Contact us for the exact time
Q:What is your Warranty?
A:We provide 1 year Warrantly
 